Zener Barrier ZbC2+

SKU: C95ZbC2+ Category: Tags: , Brand:
BRAND
ZbC2+

The Zener barrier ZbC2+ is a certified intrinsically safe interface. It is used to connect a certified intrinsically safe device located in a potentially explosive atmosphere (Hazardous area) to a non-certified device that is in a safe area.

The Zener barrier prevents the transfer of unacceptably high energy from the safe area into the hazardous area. The ZbC2+ Zener barrier contains two identical diode return barriers in a common housing and it is designed for DIN rail mounting in a safe area.

Technical data

Measured value


Temperature

Relative humidity

BARRIER TYPE AND DESIGN

Two identical Zener barriers ZB1 and ZB2 in the common housing
Positive polarity with return diode

ELECTRICAL SPECIFICATION

Nominal resistance Ro
310 Ω
Fuse rating
40 mA
Series resistance
Rs1 = 355 Ω (terminals 1-5, terminals 3-7)
Rs2 = 42 Ω (terminals 2-6, terminals 4-8)
Voltage drop across return diode
0.8 V
Working voltage (SAFE terminals)
max. 26 V at current of less than 10 uA

GENERAL TECHNICAL DATA

Operating temperature range
-20 to +60 °C
Dimensions
22,5 x 114 x 100 mm
Weight
125 g
Warranty
3 years

DATA FOR APPLICATION IN CONNECTION WITH HAZARDOUS AREAS

Directive conformity
2014/34/EU
Compliance with standards
EN IEC 60079-0:2018, EN 60079-11:2012
Certificate
FTZU 22 ATEX 0018X
Identification marking
EX ll (3)G [Ex ic Gc] IIC
Voltage Uo
29,4 V
Current Io
96 mA
Resistance Ro
min. 306 Ω
Capacitance Co + Induktance Lo
120 nF + 2 mH or 60 nF + 4 mH
Maximum safe voltage
250 V

  • code
    ZbC2+
  • Reviews

    There are no reviews yet.